ExAC Section 2 Sample Exam — 10 Free Questions

Section 2 focuses entirely on the National Building Code of Canada 2020 (NBC 2020) and the National Energy Code for Buildings (NECB). It is the only ExAC section where candidates are permitted to bring a tabbed copy of the NBC into the exam room. The full section has about 75 multiple-choice questions over three hours, with no written answers. Questions test your ability to navigate the code quickly and accurately across occupancy classification, fire safety, means of egress, barrier-free accessibility, structural loading, and energy performance requirements for Canadian buildings.

These ten sample questions reflect the range of topics and code references you will encounter in the full Section 2 exam. Strong performance here depends less on memorization and more on knowing where to find each requirement in the NBC and understanding how individual clauses apply to specific building scenarios. After each question, the rationale identifies the relevant code clause and explains the correct reasoning. The full Issued for Interns study guide includes NBC tab guides, annotated code references, and full-length timed Section 2 mock exams.

Practise with your tabbed NBC open beside you — Section 2 rewards knowing where to look, not memorizing clauses. Every question in this sample is written by candidates who sat and passed the ExAC, to give you a sense of what you will face on exam day.

Loading sample questions…
Section 2 sample questions & answer explanations

Here are all ten Section 2 sample questions in full. Read each question, choose your answer, then expand the explanation to see the correct choice and the reasoning behind it — the same detailed rationale included with every question in the full study guide.

  1. Question 1Theme 5

    A nursing home provides 24-hour care for 30 elderly residents with cognitive impairments. The facility is not a single detached housekeeping unit. Which NBC 2020 major occupancy classification applies?

    • AGroup C — Residential (sleeping accommodation not associated with care or treatment)
    • BGroup D — Business and Personal Services (healthcare is a personal service)
    • CGroup B, Division 3 — Care occupancy (care provided to residents, other than home-type care)
    • DGroup B, Division 2 — Treatment occupancy (overnight accommodation to facilitate treatment)
    Show answer & explanation

    Correct answer: Group B, Division 3 — Care occupancy (care provided to residents, other than home-type care)

    Division A, Article 1.4.1.2. defines a care occupancy (Group B, Division 3) as the occupancy or use of a building or part thereof, other than a home-type care occupancy, where care is provided to residents. A nursing home fits this exactly. Group B, Division 2 (treatment occupancy) is where treatment is provided and overnight accommodation is available to facilitate that treatment — a hospital. Group C (residential) is expressly for persons who are NOT harboured for the purpose of receiving care or treatment. Group B, Division 4 (home-type care) is limited to a single detached housekeeping unit, which this facility is not. Note that the NBC definition of care occupancy contains no '10 or more persons' threshold; the 10-person figure appears in Article 3.1.2.5., which permits convalescent homes and children's custodial homes to be classified as residential where occupants are ambulatory and live as a single housekeeping unit with sleeping accommodation for not more than 10 persons.

  2. Question 2Theme 5

    A new 8-storey office building provides a fully automatic sprinkler system throughout. Which of the following is a code-recognized trade-off that sprinkler protection may permit?

    • AElimination of the required fire alarm system, since sprinklers provide adequate occupant warning
    • BElimination of all fire-resistance rated construction, since active suppression replaces passive protection
    • CIncreased maximum travel distance to exits, and possibly a larger permitted area or relaxed construction type
    • DReduction of exit widths by 50%, since sprinklers extend evacuation time
    Show answer & explanation

    Correct answer: Increased maximum travel distance to exits, and possibly a larger permitted area or relaxed construction type

    The NBC grants specific allowances to buildings that are sprinklered throughout. The maximum travel distance in a Group D floor area rises from 40 m to 45 m when it is sprinklered throughout (Sentence 3.4.2.5.(1)), and the building-size Articles permit larger areas and, in some cases, combustible construction where sprinklers are provided — a 3-storey Group D building may have a building area of 4 800 m² sprinklered (Article 3.2.2.63.) against 1 600 m² unsprinklered facing one street (Article 3.2.2.62.). Above 6 storeys, every Group D building-size Article requires sprinklers. Sprinklers do NOT remove the fire alarm system — Sentence 3.2.4.1.(1) requires a fire alarm system in buildings in which an automatic sprinkler system is installed — and they do not remove the fire-resistance ratings required for floor assemblies and loadbearing elements.

  3. Question 3Theme 5

    What is the correct sequence of compliance logic when pursuing an Alternative Solution under the NBC 2020?

    • ADivision C (permit application) → Division B (prescriptive deviation) → AHJ approval → occupancy
    • BAHJ pre-consultation review → Division A (objectives) → Division B (modified requirements) → building permit issuance and inspection
    • CFind the departed solutions and their objectives → propose the alternative → show equal performance (Division C) → submit with permit
    • DDivision B prescriptive review → independent engineering analysis → Division C permit application → post-construction AHJ sign-off of the alternative
    Show answer & explanation

    Correct answer: Find the departed solutions and their objectives → propose the alternative → show equal performance (Division C) → submit with permit

    Clause 1.2.1.1.(1)(b) of Division A permits alternative solutions that achieve at least the minimum level of performance required by Division B in the areas defined by the objectives and functional statements attributed to the applicable acceptable solutions, and Article 1.1.2.1. of Division B points to where those attributions are listed (e.g. Section 3.10. for Part 3). Note A-1.2.1.1.(1)(b) explains that the alternative must perform 'as well as', not 'well enough', that all applicable acceptable solutions must be considered, and that where Division B offers several designs, the one providing the lowest level of performance generally sets the minimum. Article 2.3.1.1. of Division C then requires the person requesting the alternative solution to document it: a Code analysis identifying the applicable objectives, functional statements and acceptable solutions and the assumptions, tests or engineering studies relied on; any special maintenance or operational requirements; and the qualifications of the designer — with one person co-ordinating where several share responsibility. The sequence starts from what the replaced acceptable solutions were attributed to, not from the permit or a post-construction sign-off.

  4. Question 4Theme 5

    What is an 'encapsulation rating' as defined by the NBC 2020?

    • AThe time in hours that a structural member can support its full design load during a standard fire test
    • BThe minimum thickness of gypsum board required over any exposed wood surface in a noncombustible building
    • CThe percentage of a mass timber surface that must be covered by noncombustible cladding
    • DThe time in minutes that a material or assembly delays ignition of encapsulated mass timber exposed to fire
    Show answer & explanation

    Correct answer: The time in minutes that a material or assembly delays ignition of encapsulated mass timber exposed to fire

    Per NBC Division A, Article 1.4.1.2., the encapsulation rating is defined as 'the time in minutes that a material or assembly of materials will delay the ignition and combustion of encapsulated mass timber elements when it is exposed to fire under specified conditions of test and performance criteria, or as otherwise prescribed by this Code.' This is distinct from a fire-resistance rating, defined as the time a material or assembly will withstand the passage of flame and the transmission of heat. The encapsulation rating specifically addresses the protection of the underlying timber structure.

  5. Question 5Theme 5

    Compare the minimum standards for the vertical rise of an individual step on (i) a stair within a single dwelling unit, and (ii) a stair serving a public corridor in a business occupancy. Which statement correctly describes the permitted rise for each?

    • ABoth are limited to a maximum rise of 180 mm; only the minimum rise differs between the two
    • BThe dwelling-unit stair is permitted a maximum rise of 200 mm, while the public stair is capped at a maximum rise of 180 mm; both share the same 125 mm minimum rise
    • CThe public stair is permitted a steeper maximum rise than the dwelling-unit stair, on the assumption that public stairs are used more efficiently by a larger number of occupants
    • DMaximum rise is not regulated for either stair type; only tread run is limited
    Show answer & explanation

    Correct answer: The dwelling-unit stair is permitted a maximum rise of 200 mm, while the public stair is capped at a maximum rise of 180 mm; both share the same 125 mm minimum rise

    Private stairs (serving a single dwelling unit, a house with a secondary suite, or a garage serving either) are permitted a rise of 125 mm to 200 mm. Public stairs (all other stairs) are held to a narrower range of 125 mm to 180 mm — a lower maximum rise. Both are measured nosing to nosing.

  6. Question 6Theme 5

    A Group D (Business) office building has the floor level of its top storey at 28 m above grade. For every storey above the first storey, the cumulative occupant load on or above that storey, divided by 1.8 times the width in metres of all exit stairs at that storey, is at most 180. Do the NBC's additional requirements for high buildings apply to this building?

    • AYes — any building with a floor level more than 18 m above grade is a high building under 3.2.6
    • BNo — for Group D it applies above 36 m, or above 18 m only where that ratio exceeds 300; neither is met here
    • CYes — at 28 m the building exceeds 6 storeys, which is the trigger for the high building provisions in 3.2.6
    • DNo — Subsection 3.2.6 applies only to buildings containing Group B or Group C major occupancies
    Show answer & explanation

    Correct answer: No — for Group D it applies above 36 m, or above 18 m only where that ratio exceeds 300; neither is met here

    Clause 3.2.6.1.(1)(a) applies Subsection 3.2.6. to a Group A, D, E or F building that is more than (i) 36 m high measured between grade and the floor level of the top storey, or (ii) 18 m high measured the same way AND in which the cumulative or total occupant load on or above any storey above grade, other than the first storey, divided by 1.8 times the width in metres of all exit stairs at that storey, exceeds 300. At 28 m the building is below the 36 m trigger, and the ratio of 180 is below the 300 trigger, so neither limb of Clause (1)(a) is engaged. The NBC deliberately does not use a single 18 m rule for all occupancies. Group B and Group C buildings are caught at 18 m (Clauses (1)(b) and (1)(d)), Group B, Division 2 or 3 floor areas above the third storey are caught at any height (Clause (1)(c)), and Group A, D, E and F buildings are caught at 36 m unless the occupant load is high relative to exit stair width.

  7. Question 7Theme 5

    A hospital (Group B, Division 2) proposes a four-storey open volume linking the inpatient floors, each of which contains patient sleeping rooms. What does NBC 2020 permit?

    • AIt is not permitted — a B-2 floor area with sleeping rooms cannot be part of an interconnected floor space
    • BIt is permitted, provided the building is sprinklered throughout and each floor is separately vented
    • CIt is permitted, provided a mechanical smoke exhaust system conforming to Article 3.2.8.7. is installed and tested
    • DIt is permitted, provided the open volume does not connect more than three storeys of the hospital
    Show answer & explanation

    Correct answer: It is not permitted — a B-2 floor area with sleeping rooms cannot be part of an interconnected floor space

    Sentence 3.2.8.1.(3) is an outright prohibition: a floor area containing sleeping rooms in a building of Group B, Division 2 major occupancy shall not be constructed as part of an interconnected floor space. No smoke control, sprinkler or venting measure buys the design out of it. It fits the strategy built into Article 3.3.3.5.: floor areas with sleeping rooms for more than 10 patients or residents are divided into fire compartments so that occupants can be moved into an adjoining compartment on the same storey.

  8. Question 8Theme 5

    A 6-storey mixed-use building has the following program: ground floor restaurant (800 m²), floors 2-3 with offices, floors 4-6 with residential apartments, and a 2-level underground parking garage. Which NBC classification statement CORRECTLY describes this building?

    • APart 9 governs — offices (Group D) and residential (Group C) are the dominant uses; the restaurant is minor
    • BPart 3 governs the ground-floor restaurant only; Part 9 governs the residential and office floors because they are separate occupancies
    • CPart 3 governs only because of building height (6 storeys); if the restaurant were removed, Part 9 would govern the residential and office floors
    • DPart 3 governs the whole building — the Group A-2 restaurant always triggers it, and so does the 6-storey height
    Show answer & explanation

    Correct answer: Part 3 governs the whole building — the Group A-2 restaurant always triggers it, and so does the 6-storey height

    This building triggers Part 3 through two independent paths: (1) The ground-floor restaurant is Group A, Division 2 (Note A-3.1.2.1.(1) lists restaurants there), and Clause 1.3.3.2.(1)(b) of Division A places every building used for a Group A major occupancy under Part 3 — the ENTIRE building, not just the ground floor. The classification follows the building. (2) The building is 6 storeys, which independently exceeds the 3-storey threshold triggering Part 3 for Groups C and D. Part 3 cannot be applied floor-by-floor in a multi-occupancy building. The underground parking garage also falls under Part 3 as it is part of the same building. The claim that removing the restaurant would return the building to Part 9 is also wrong: a 6-storey mixed-use building still exceeds the 3-storey Part 9 threshold on its own.

  9. Question 9Theme 5

    An architect's floor plan for an unsprinklered floor area with no public corridor shows two exit stairs. The floor area is rectangular, 60 m × 30 m (maximum diagonal ≈ 67 m). Both exit stairs are located at the east end of the building, 7 m apart, with no fire separation dividing the floor area between them. Does this exit placement comply with the NBC?

    • AYes — the NBC only requires a minimum of 9 m between exits, and 7 m is close enough with a reasonable tolerance
    • BNo — without a public corridor, exits must be at least half the diagonal (≈33.5 m) and 9 m apart; 7 m fails both
    • CYes — the half-diagonal rule applies only to sprinklered buildings; unsprinklered buildings have no minimum exit separation
    • DNo — exits must always be at opposite ends of the floor area, regardless of diagonal dimension
    Show answer & explanation

    Correct answer: No — without a public corridor, exits must be at least half the diagonal (≈33.5 m) and 9 m apart; 7 m fails both

    Clause 3.4.2.3.(1)(b) requires that for floor areas without a public corridor, the minimum distance between two exits be at least one half the maximum diagonal dimension but not less than 9 m. The diagonal of a 60 × 30 m rectangle is approximately 67 m (√(3600 + 900) ≈ 67.1 m). Half of 67 m ≈ 33.5 m. The exits at 7 m apart fail on both counts: they are less than the 33.5 m half-diagonal requirement AND less than the 9 m absolute minimum. Clustering both exits at one end creates a critical life-safety deficiency — a fire near the east end could block both exits simultaneously. Sentence 3.4.2.3.(3) measures the distance as the shortest path smoke would travel between the exits, and Sentence (2) — which waives the rule where a fire separation divides the floor area with at least one third on each side — does not apply here. Even with a public corridor, Clause (1)(a) would still require 9 m. This question requires candidates to perform the diagonal calculation and apply two overlapping thresholds.

  10. Question 10Theme 5

    Under the NECB 2020 simple trade-off path (Section 3.3.), an architect wants to offset an oversized glazed curtain wall (a vertical above-ground fenestration assembly) by improving the thermal performance of the roof (a horizontal above-ground assembly). Is this trade permitted?

    • ANo — vertical components trade only with vertical, and horizontal only with horizontal
    • BYes — any above-ground component may be traded against any other, provided total building envelope heat loss does not increase
    • CYes, but only if the building also adds a compensating skylight to balance the trade proportionally between vertical and horizontal surfaces
    • DNo — the simple trade-off path does not permit any trade involving fenestration; only opaque assemblies may be traded against each other
    Show answer & explanation

    Correct answer: No — vertical components trade only with vertical, and horizontal only with horizontal

    Sentences 3.3.1.1.(3) and (4) restrict the simple trade-off path: vertical above-ground portions of the building envelope may only be traded off against other vertical above-ground portions, and horizontal above-ground portions only against other horizontal above-ground portions. A vertical fenestration deficit cannot be offset by improving a horizontal roof assembly — the two calculations are kept separate.